Techie Allison has found that by tweaking a few bytes inside the FMC_II.PRG file, you can get past it's problem of only lasting until 1999. |
Techie Allison has found that by tweaking a few bytes inside the FMC_II.PRG file, you can get past it's problem of only lasting until 1999. |
||
+ | |||
+ | The hardware RTC (Real-Time Clock) is fine, it's just the software that can't set it. |
||
+ | |||
+ | |||
+ | '''SOLUTION''' |
||
FINDINGS |
FINDINGS |
||
− | ======= |
||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
− | Location: |
+ | ''Location:'' 000D7D |
− | Original Value |
+ | ''Original Value:'' 50h |
+ | |||
⚫ | |||
+ | |||
⚫ | |||
⚫ | |||
When click UP, this is the value we roll around to. Clicking on '99 will rollover to this number. |
When click UP, this is the value we roll around to. Clicking on '99 will rollover to this number. |
||
− | Location: 000EE7 |
+ | ''Location:'' 000EE7 |
− | Original Value |
+ | ''Original Value:'' 63h |
This is the maximum year we can go to, when clicking UP. |
This is the maximum year we can go to, when clicking UP. |
||
− | PROPOSALS |
+ | '''PROPOSALS''' |
+ | |||
− | ======== |
||
Ideally we want to count from 00 to 99 and to rollover from 99 to 0. |
Ideally we want to count from 00 to 99 and to rollover from 99 to 0. |
||
The following changes are to be made; |
The following changes are to be made; |
||
− | Location: 000D7D |
+ | ''Location:'' 000D7D |
− | Original Value |
+ | ''Original Value:'' 50h |
− | New Value: 00h |
+ | ''New Value:'' 00h |
− | Location: 000EF2 |
+ | ''Location:'' 000EF2 |
− | Original Value |
+ | ''Original Value:'' 50h |
− | New Value: 00h |
+ | ''New Value:'' 00h |
− | TESTING |
+ | '''TESTING''' |
+ | |||
− | ====== |
||
Within Steem seems functional. Occassionally causes bombs. No clock cartridge. But counters apparently functional. |
Within Steem seems functional. Occassionally causes bombs. No clock cartridge. But counters apparently functional. |
||
On a 4Mb STFM... IT DOES NOT WORK!!! |
On a 4Mb STFM... IT DOES NOT WORK!!! |
||
− | FAILURE!!!!! |
+ | '''FAILURE!!!!!''' |
+ | |||
− | ======== |
||
When setting the FMCII cartridge. ANY number BELOW 80 causes an error, "Incorrect number of days in month." |
When setting the FMCII cartridge. ANY number BELOW 80 causes an error, "Incorrect number of days in month." |
||
− | CONCLUSION |
+ | '''CONCLUSION''' |
− | ========= |
||
− | WE CANNOT HAVE THE COUNTER RUNNING FROM 0 thru 99. |
||
+ | We CANNOT have the counter running from 0 through to 99. |
||
+ | |||
+ | |||
⚫ | |||
⚫ | |||
− | ======== |
||
Revert to original idea, of setting past 1999. 80 must be the MINIMUM value. 128 will be the MAXIMUM value, thus a maximum year of 2028 |
Revert to original idea, of setting past 1999. 80 must be the MINIMUM value. 128 will be the MAXIMUM value, thus a maximum year of 2028 |
||
− | Location: 000D87 |
+ | ''Location:'' 000D87 |
− | Original Value |
+ | ''Original Value:'' 63h |
− | New Value: 80h |
+ | ''New Value:'' 80h |
− | Location: 000EE7 |
+ | ''Location:'' 000EE7 |
− | Original Value |
+ | ''Original Value:'' 63h |
− | New Value: 80h |
+ | ''New Value:'' 80h |
− | MAXIMUM YEAR OF FMCII |
+ | '''MAXIMUM YEAR OF FMCII''' |
+ | |||
− | ================= |
||
Testing indicates that 2059 is the maximum year. We will therefore release this as FMCII_9F.PRG. 9F is 159 in decimal. |
Testing indicates that 2059 is the maximum year. We will therefore release this as FMCII_9F.PRG. 9F is 159 in decimal. |
||
+ | |||
+ | For the patched version of FMCII.PRG, you'll need to visit the thread on the Atari Forum [https://www.atari-forum.com/viewtopic.php?t=9651] |
||
+ | |||
+ | |||
+ | Back to [Fixes] |
Revision as of 12:55, 22 September 2006
Fixing the Forget-Me-Not Clock software
Techie Allison has found that by tweaking a few bytes inside the FMC_II.PRG file, you can get past it's problem of only lasting until 1999.
The hardware RTC (Real-Time Clock) is fine, it's just the software that can't set it.
SOLUTION
FINDINGS
Location: 000D87 Original Value: 63h
When clicking DOWN, this is the maximum year value we roll around to. If the year is 80, and we click down, it rolls round to 99. This is that '99 value for the year 1999.
Location: 000D7D
Original Value: 50h
When clicking DOWN, this is the lowest value we can go before it rolls over. This is the minimum year. This is that '80 (1980) value. When we hit this number, it rolls around.
Location: 000EF2 Original Value: 50h
When click UP, this is the value we roll around to. Clicking on '99 will rollover to this number.
Location: 000EE7 Original Value: 63h
This is the maximum year we can go to, when clicking UP.
PROPOSALS
Ideally we want to count from 00 to 99 and to rollover from 99 to 0.
The following changes are to be made;
Location: 000D7D Original Value: 50h New Value: 00h
Location: 000EF2 Original Value: 50h New Value: 00h
TESTING
Within Steem seems functional. Occassionally causes bombs. No clock cartridge. But counters apparently functional.
On a 4Mb STFM... IT DOES NOT WORK!!!
FAILURE!!!!!
When setting the FMCII cartridge. ANY number BELOW 80 causes an error, "Incorrect number of days in month."
CONCLUSION
We CANNOT have the counter running from 0 through to 99.
PROPOSALS
Revert to original idea, of setting past 1999. 80 must be the MINIMUM value. 128 will be the MAXIMUM value, thus a maximum year of 2028
Location: 000D87 Original Value: 63h New Value: 80h
Location: 000EE7 Original Value: 63h New Value: 80h
MAXIMUM YEAR OF FMCII
Testing indicates that 2059 is the maximum year. We will therefore release this as FMCII_9F.PRG. 9F is 159 in decimal.
For the patched version of FMCII.PRG, you'll need to visit the thread on the Atari Forum [1]